High Surge Loads; Over-Temperature Conditions - Xantrex Freedom EX 4000 Owner's Manual

Inverter/charger with 48vdc-to-12vdc converter
Hide thumbs Also See for Freedom EX 4000:
Table of Contents

Advertisement

Operating Limits
Figure 6 Overload characteristics
210
200
190
180
170
160
150
140
130
120
Thermally limited performance
110
100
1
10
26
100
Time (sec)

High Surge Loads

Some induction motors used in freezers, pumps, and other motor-
operated equipment require high surge currents to start. The
Freedom EX 4000 may not be able to start some of these motors
even though their rated steady state current draw is within the
inverter/charger/converter's limits. The unit will shut down and
indicate an overload shutdown.

Over-temperature Conditions

During inverter operation, when the Freedom EX 4000's internal
temperature starts to approach its preset shutdown limit, if
installed, the display on the Freedom EX Remote Panel (PN: 808-
0817-03) will show error code E07. The Event LED will flash.
If the over-temperature condition persists, if installed, the display
on the Freedom EX Remote Panel (PN: 808-0817-03) will show
error code E04. The Event LED will turn on and the
inverter/charger/converter will shut down to prevent damage to the
1000
inverter/charger/converter and protect the battery from being over-
discharged.
Freedom EX 4000 Owner's Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

820-4080-4

Table of Contents