Adjusting Settings in Configuration Mode
Setting
Setting Name
Number
C4
Charge Cycle
C5
Recharge Voltage
C6
Absorption Time
C7
Default Battery
Temperature
36
Default
Range of Values
Value
3St
3St (3-stage)
vCC (CVCC)
2st (2-stage)
50.0
(LBCO or) 44.0 to 56.0
30
5 to 480
v+n
CLD(Cool)
v+n(Warm)
HOT(Hot)
Unit Step
--
--
Sets the charging method to either 3-stage,
constant voltage constant current, or 2-stage.
Not applicable when LFP battery type is
selected.
V
0.1
Sets the battery voltage level at which a new
charge cycle begins. The minimum value is the
higher of LBCO or 44V. If LBCO is set to
greater than Recharge Voltage, this value will
change to match the LBCO level.
m
5
Sets the time (in minutes) spent in the
Absorption stage before transitioning to the
next charge stage.
--
--
Selects the battery temperature charging
compensation if a battery temperature sensor
(BTS) is not installed. In the absence of a BTS,
the charger uses either Cool = 5 °C, Warm =
25 °C, or Hot = 40 °C. Not applicable when LFP
battery type is selected.
Description
Freedom EX 4000 Owner's Guide