General Settings - Xantrex Freedom EX 4000 Owner's Manual

Inverter/charger with 48vdc-to-12vdc converter
Hide thumbs Also See for Freedom EX 4000:
Table of Contents

Advertisement

Adjusting Settings in Configuration Mode

General Settings

NOTE: See Abbreviations and Acronyms on page iv.
Setting
Setting Name
Number
01
Inverter Mode
Battery Mode
02
Search Mode
03
AC Breaker Rating
32
Default
Range of Values
Value
1vE
1vE (enable)
(enable)
1vD (disable)
DIS
DIS (disable)
(disable)
enA (enable)
50.0
3.0 to 50.0
Unit Step
--
--
Enables or disables Invert mode also known as
Battery mode. When enabled and when the
battery is sufficiently charged, the Freedom EX
4000 converts battery power to AC power.
--
--
Enables or disables Search mode also known
as load sensing mode. When enabled, the
Freedom EX 4000's "no load" loss can be
reduced further when the total load is less than
the Search threshold setting.
Enable Search mode in parallel stacking*.
Search mode is not supported in series
stacking*.
* Contact Xantrex prior to stacking two Freedom EX 4000 units together.
Stacking configuration via USB is a required step to enable stacking.
A
1.0
The load share feature prioritizes the AC load
by reducing the charge current in order to
maintain the total input current to less than the
Load share setting.
Description
Freedom EX 4000 Owner's Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

820-4080-4

Table of Contents