Charger Sub-settings
Setting
Setting Name
Number
C1
Battery Type
C2
Battery Capacity
C3
Maximum Charge
Current
975-0999-01-01
Default
Range of Values
Value
FLD
FLD (Flooded),
GEL(Gel),
USE (Custom),
LFP (LiFePO
),
4
AGn (AGM),
10
0 to 300
80
4 to 80
Adjusting Settings in Configuration Mode
Unit Step
--
--
Sets the corresponding battery type to the
actual battery used in the power system.
LFP (LiFePO
) is a pre-set battery type that
4
requires a compatible Xantrex Battery with
BMS. Other lithium-ion batteries with BMS
should be set as USE (Custom) battery type
with parameters set according to the battery
manufacturer's specifications.
Ah
1 (0
Sets the battery capacity of the system. The
to
value displayed must be multiplied by a factor
10)
of 10 for the real value. For example, the
default 100Ah is displayed as 10, 1200Ah will
10 
show as 120, 10Ah will show as 1.
(10-
300)
A
1
Sets the maximum DC output current that is
available to the charger.