6
FORK, TRIPLE CLAMP
When the vacuum gauge reaches the required value, turn control lever
0
to
voir
Equalize pressure.
Guideline
10 mbar
✓ The pressure gauge increases to the required value.
0 bar
When the pressure gauge reaches the required value, turn control lever
C,
Damper
Guideline
0 bar
✓ Oil is pumped into the cartridge.
✓ The pressure gauge increases to the required value.
3 bar
When the pressure gauge reaches the required value, turn control lever
C,
Damper
Guideline
3 bar
✓ The pressure gauge drops to the required value.
0 bar
When the pressure gauge reaches the required value, activate the
Guideline
0 bar
✓ The vacuum pump is switched off.
Disconnect the vacuum pump. Remove the special tool.
Info
I
The filling port must be positioned at the highest point.
Mount and tighten the filling screw with the O-ring.
Guideline
I
Cartridge filling screw
200889-10
e with nitro en
Clamp the cartridge in a vise using soft jaws.
Info
I
Clamp the cartridge only lightly.
Connect the connector of the special tool to the pressure regulator of the nitrogen
bottle.
Nitrogen charging tool (T14019) ("" p. 231)
Filling gas - nitrogen
200890-10
Adjust the pressure regulator of the nitrogen bottle.
Guideline
I
Gas pressure
Pierce the membrane with the needle of the special tool.
Open valve
to
Pressure.
to
Vacuum.
O.
On/Off
M4x0.5
I 2 Nm (1.5 lbf ft)
1.2 bar (17 psi)