Adjusting The Valve Clearance; Installing The Starter Motor - Husqvarna FC 350 2014 Repair Manual

Table of Contents

Advertisement

17
ENGINE
17.5.28

Adjusting the valve clearance

17.5.29

Installing the starter motor

-
Position the engine at ignition top dead center.
G
✓ Markings
on the cylinder head are flush above the flat areas
camshafts.
-
Check the valve clearance at all valves between the camshaft and cam levers.
Guideline
Valve clearance
Intake at: 20 °c (68 °F)
Exhaust at: 20 °C (68 °F)
I
Feeler gauge (590290411 00) (or p. 223)
If the valve clearance does not meet specifications:
-
Adjust the valve clearance. (or p. 184)
-
Mount and tighten screw
Guideline
I
Screw plug, crankshaft location
Main work
-
Remove the timing chain tensioner. (or p. 134)
-
Remove the camshaft. (or p. 134)
O.
-
Raise cam levers
-
Correct the shims according to the findings from checking the valve clearance.
-
Install the camshafts. (or p. 181)
-
Install the timing chain tensioner. (or p. 183)
Finishing work
-
Check the valve clearance. (or p. 183)
-
Grease the O-ring. Position the starter motor.
O
-
Mount screws
but do not tighten yet.
Guideline
I
Screw, starter motor
I
0.10 ... 0.15 mm (0.0039 ... 0.0059 in)
I
0.13 ... 0.18 mm (0.0051 ... 0.0071 in)
O
with the washer.
184
C,
of the
10 Nm (7.4 lbf ft)
I10Nm(7.41bf ft)

Advertisement

Table of Contents
loading

Table of Contents