15
WIRING HARNESS, BATTERY
15.4
Checking the charging voltage
r
-
ti ,
. .
- �� '. ""
-,
_ _
';:!QI
,\,
"""'
/.
- �
..i.. .....:
..
' '"V"
�,.,
v
.. .
.
-c;:.A.
0
' "--'-
. ..
7
/,
..
-
Main work
-
Insert the battery into the battery compartment with the terminals facing to the
front.
I
Battery (YTXSL-BS) (,... p. 205)
Reconnect rubber band
Info
I
Contact disk
with the claws facing down.
-
Position the positive cable and mount and tighten the screw.
Guideline
Screw, battery terminal
-
Slide positive terminal cover @ over the positive terminal.
-
Position the negative cable and mount and tighten the screw.
Guideline
Screw, battery terminal
-
Slide negative terminal cover
Finishing work
-
Mount the seat. (,... p. 80)
Condition
The battery must be fully functional and completely charged.
Preparatory work
-
.
_
Remove the seat. (,... p. 80)
Main work
-
Pull back the positive terminal cover.
-
Start the motorcycle for a check. (,... p. 11)
�I
Measure the voltage between the specified points.
t
Measuring point
-
Charging voltage
I
5,000 rpm
If the displayed value is less than the specified value:
-
I• I
I
Check the plug-in connections from the alternator to the voltage regulator.
-
Check the plug-in connections from the voltage regulator to the wiring
harness.
-
Check the stator winding of the alternator. (,... p. 199)
If the displayed value is greater than the specified value:
-
Change the voltage regulator.
Finishing work
-
Mount the seat. (,... p. 80)
O.
e
must be mounted between screw
MS
MS
over the negative terminal.
(D
(+) - Measuring point
Plus
113.5 ... 15.0 V
106
e
and cable lug
0
2.5 Nm
(1.84 lbf ft)
2.5 Nm
(1.84 lbf ft)
(-)
Ground