Metric Bolt Specifications Bolting Into Cast Aluminum; Flare-Type Hydraulic Fittings - MacDon R85 Operator's Manual

Rotary disc 13-foot self-propelled windrower header
Table of Contents

Advertisement

7.2.3 Metric Bolt Specifications Bolting into Cast Aluminum
Table 7.9 Metric Bolt Bolting into Cast Aluminum
Nominal
8.8
Size (A)
(Cast Aluminum)
ft·lbf
M3
M4
M5
M6
6
M8
14
M10
28
M12
52
M14
M16

7.2.4 Flare-Type Hydraulic Fittings

1. Check flare (A) and flare seat (B) for defects that might
cause leakage.
2. Align tube (C) with fitting (D), and thread nut (E) onto
fitting without lubrication until contact has been made
between the flared surfaces.
3. Torque the fitting nut (E) to the specified number of
flats from finger tight (FFFT) or to a given torque
value shown in Table
Fittings, page
102.
4. Use two wrenches to prevent fitting (D) from rotating.
Place one wrench on the fitting body (D), and tighten
nut (E) with the other wrench to the torque shown.
5. Assess the final condition of the connection.
169455
MAINTENANCE AND SERVICING
Bolt Torque
10.9
(Cast Aluminum)
N·m
ft·lbf
1
2.6
5.5
9
9
20
20
40
40
70
73
7.10 Flare-Type Hydraulic Tube
N·m
4
8
12
28
55
Figure 7.9: Bolt Grades
100
Figure 7.10: Hydraulic Fitting
101
Revision F

Advertisement

Table of Contents
loading

Table of Contents