7.2.3 Metric Bolt Specifications Bolting into Cast Aluminum
Table 7.9 Metric Bolt Bolting into Cast Aluminum
Nominal
8.8
Size (A)
(Cast Aluminum)
ft·lbf
M3
–
–
M4
–
M5
M6
6
M8
14
M10
28
M12
52
–
M14
–
M16
7.2.4 Flare-Type Hydraulic Fittings
1. Check flare (A) and flare seat (B) for defects that might
cause leakage.
2. Align tube (C) with fitting (D), and thread nut (E) onto
fitting without lubrication until contact has been made
between the flared surfaces.
3. Torque the fitting nut (E) to the specified number of
flats from finger tight (FFFT) or to a given torque
value shown in Table
Fittings, page
106.
4. Use two wrenches to prevent fitting (D) from rotating.
Place one wrench on the fitting body (D), and tighten
nut (E) with the other wrench to the torque shown.
5. Assess the final condition of the connection.
169457
MAINTENANCE AND SERVICING
Bolt Torque
10.9
(Cast Aluminum)
N·m
ft·lbf
–
1
–
2.6
–
5.5
9
9
20
20
40
40
70
73
–
–
–
–
7.10 Flare-Type Hydraulic Tube
N·m
–
4
8
12
28
55
Figure 7.9: Bolt Grades
100
–
–
Figure 7.10: Hydraulic Fitting
105
Revision G