10Specifications; 10-1.Specifications; Analog Section; Display Section - Unipulse F701-P Operation Manual

Table of Contents

Advertisement

10 SPECIFICATIONS
10
SPECIFICATIONS
10-1.
Specifications

■Analog section

Excitation voltage
Signal input range
Zero adjustment range
Span adjustment range
Minimum input sensitivity
Accuracy
A/D converter
Minimum indication resolution

■Display section

Display
Weight display
Accumulation display
Display update rate
Chapter
Unit
10
Capacity
Min scale division
Decimal place
Over display
Center zero
Status
90
90
5V DC±5%
Output current within 90mA
Ratiometric system
(Up to six 350Ω load cells can be connected in parallel.)
-0.5 to 3.0mV/V
Automatic adjustment by digital computation
-0.2 to 2.0mV/V
Automatic adjustment by digital computation
0.3 to 3.0mV/V
0.15μV/count
Non-linearity:
Within 0.01%FS
Zero drift:
0.025μV/℃RTI Typ
Gain drift:
1ppm/℃ Typ
Conversion rate:
300 times/sec
Conversion resolution: 24 bits (binary)
1/10000
18.5mm in character height
Numerical display by liquid crystal display module (7-digit)
Subdisplay 7.3mm in character height (14-digit)
5-digit
Sign: Negative sign at the highest-order digit
9-digit
* Also switchable to accumulation count (4-digit) or final (5-digit)
1, 2, 5, 10, 20 times/sec selectable (system speed: 300 times/sec)
None, g, kg, t, lb selectable
5-digit
Settable in the range of 1 to 50
0, 0.0, 0.00, 0.000 selectable
A/D converter input over
Net over
Capacity + 9 scale divisions over
Gross over
True zero point or center of each value is displayed.
NZ/ HOLD/ ZALM/ STAB/ TARE/ NET/ GROSS/ CZ/ ZT/
HI/ GO/ LO/ COMPL/ SP3/ SP2/ SP1 displayed
LOAD
OFL1
OFL2
OFL3

Advertisement

Table of Contents
loading