5 FUNCTION SETTINGS
5-4.

Moving average filter (setting mode 2-2)

This function restrains the indicated value from fluctuating by moving-averaging the A/D-
converted data.
The moving average times can be selected in the range of OFF (1 time) - 512 times. With an
increasing number of moving average times, the indicated value becomes more stable, while the
response becomes slower. On the other hand, with a decreasing number of moving average times,
the response becomes faster, while the indicated value becomes easier to fluctuate.
Set an optimum value according to the type of weighing.
5-5.

Filter in stable condition (setting mode 1-5)

This function automatically inserts the digital filter to restrain the indicated value in a stable
condition from fluctuating. Select whether or not to insert it.
Definition of stability is given by "5-6.Motion detection(MD) (setting mode 1-5, 2-3)" on page 33.
Chapter
5
32
32
F701-P
A/D
Load cell
converter
Setting frequency
"5-3Digital low pass filter
(setting mode 2-1)" on
page 31
Weighing function 2
OFF
Digital
Moving
low pass filter
average filter
Setting times
"5-4Moving average filter
(setting mode 2-2)" on
page 32
Filter in stable condition
0: Insert (256 times)
1: Not insert
When Stable is OFF or
the filter in stable condition
is not inserted.
Digital
filter
Stable
(fixed at 256 times)