8 EXTERNAL INPUT/OUTPUT SIGNALS (CONTROL CONNECTOR)
8
EXTERNAL INPUT/OUTPUT
SIGNALS (CONTROL CONNECTOR)
The input/output and internal circuits are electrically insulated by photocoupler.
There is a need to prepare external 24V DC (power supply for external input/output signal circuit)
separately.
8-1.

Connector pin assignments

* Signal can be assigned. (For details, please refer to "External input selection (Setting mode 3-7)"
- External input selection (setting mode 3-7)
Chapter
8
- External output selection (setting mode 3-8)
48
48
External input 1-4
Power supply on the outside
and "External output selection (Setting mode 3-8)")
External input selection
External output selection
External output 1-4
External input/output signal terminal block
0: G/N
3: TARE OFF
4: Accumulation clear
2: TARE ON
* If same level input signal is assigned to more than one input,
priority is given to lower-order numbers, and the other becomes
invalid.
0: COMPL.
4: HI
8: Weight Error
9: Total limit
2: SP2
6: LO
External input 1
External input 2
External input 3
External input 4
1: D/Z ON
5: HOLD/JUDGE
External output 1
External output 2
External output 3
External output 4
1: SP1
5: GO
3: SP3
7: STAB