5-8.

Digital zero(DZ)

This function forcibly zeros the gross weight. However, the gross weight exceeding the DZ
regulation value cannot be zeroed.
1.
2.
If digital zero operation is performed when gross weight > DZ regulation value, gross weight from
which the DZ regulation value is subtracted is displayed. At the same time, "
an alarm of the problem. In such a case, take the following measures.
Change the DZ regulation value setting, and perform digital zero operation again.
(However, since this is a temporary measure, zero calibration should be performed early.)
Remove weighing residue adhering to the tank, etc.
Check around the load cell (scale) for mechanical contacts.
5-9.

Digital zero clear

This function clears the zero point correction amount by digital zero operation.
By performing this operation, the zero point is brought back to the state in which zero calibration
was registered. Also, "
1.
2.
5-10.
DZ regulation value (setting mode 4-4)
Set the range of zero point correction amount (deviation from the zero calibration point) by digital
zero and zero tracking. If digital zero operation is performed or zero tracking is actuated where the
DZ regulation value is exceeded, "
(Input range/0 - 9999)
5-11.
Gross weight display/net weight display
The F701-P can display gross weight or net weight selectively. Switch between gross weight
display and net weight display with the
is performed between gross weight display and net weight display alternately. When gross weight is
displayed, "
The display is as follows: Net weight = Gross weight - Tare weight
The tare weight is determined by tare subtraction. The tare subtraction includes one-touch tare
subtraction and digital tare subtraction.
35
Press the
key once.
The gross weight is zeroed.
" if blinking, goes out.
Press the
key while pressing the
The zero point correction amount is cleared.
" goes out, and when net weight is displayed, "
Measure
key.
" blinks to give an alarm.
key. Each time the
" lights.
5 FUNCTION SETTINGS
" flashes to give