6 WEIGHING SETTING AND OPERATIONS
6-6.

About accumulation

The timing which makes a weight value accumulate is as follows by comparison mode (setting
mode 1-4).
- Upper/lower limit comparison mode / over/under comparison mode
Accumulation is performed when the near zero signal is OFF and stable signal is ON.
After the last completion of measurement, when near zero turns ON, it is judged as a state
measurable next time.
- Discharging control mode
Accumulation is performed at the timing of outputting the complete signal.
* It does not accumulate if a measurement result is minus data, or when overscale.
6-7.

Total comparison selection/total limit/count limit

Comparison can be made with respect to the accumulation value or accumulation count.
- Total comparison selection
Select the comparison target from
Comparison OFF/ Total comparison ON/ Count comparison ON.
Chapter
6
- Total limit (high 4)
Set the value of four high-order digits for total comparison.
(Input range/0 - 9999)
- Total limit (under 5)
Set the value of five low-order digits for total comparison.
(Input range/0 - 99999)
- Count limit
Set the value for count comparison.
(Input range/0 - 9999)
6-8.

Accumulation clear

This function clears the accumulated data (count and accumulation value).
46
46
Comparison OFF:
Total comparison ON:
Count comparison ON:
1.
Press the
key.
2.
If
key is pressed, accumulation count and accumulation value is zeroed.
Comparison is not made.
The total limit signal is output when the accumulation value
≧ total limit setting value.
The total limit signal is output when the accumulation count
≧ count limit setting value.
Blinking display.