EBARA EV-A Series Instruction Manual page 41

Dry vacuum pump
Table of Contents

Advertisement

Oil refill is required when the level is below lower limit. Refill the oil following the procedure bellow.
(1) Stop the pump. Remove the packaging covers.
(2) Wait until pump internal pressure becomes atmospheric and cool enough. Then remove the filler
plug.
(3) Refill oil as checking the level up to the center of red circle on the gauge.
(4) Clean the o-ring and place it on the plug, then put it back and tighten securely.
(5) Perform leak check after the oil refill.
Use lubricant oil specified on P.18 (3.4. Product specification) section.
Do not overfill more than upper limit as it may damage the product.
Refill lubricant oil immediately when oil level is low as it may cause severe damages to the
product.
Repair service may be necessary if the product requires frequent oil refill.
Contact one of the office listed in the back of this manual.
PM10U
Inlet NW40
Filler plug
Photo 7.2 Filler plug and oil level gauge position
CAUTION
Outlet NW25
Oil levl gauge
EBARA
CORPORATION
P.41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ev-a06Ev-a06-1Ev-a06-2Ev-a06-3

Table of Contents