(1)
POWER Lamp
(2)
ALARM Lamp
(3)
PROGRAM Lamp
(4)
RUN Lamp
(5)
MONITOR Lamp(Hz)
(6)
MONITOR Lamp(A)
(7)
LOCAL/REMOTE Lamp
(8)
LED Indicator
(9)
RUN switch
(10)
STOP/REST Switch
(11)
ESC Switch
(12)
Up Switch
(13)
Down Switch
(14)
SET Switch
PM10U
Table. 5.1 Explanation of operation panel.
Name
Lights up when power is supplied
Lights up in red when inverter trips
Does not light up
Lights up when running
Lights up when LED display indicates frequency
Lights up when LED display indicates current
Lights up when running in local mode(light out in remote mode)
Indicate run time, rotation speed and inverter 2ndary side current
Starts up the pump (Only in local mode)
Stops the pump, and reset
Switches between LED indicator and group code
Operates data indicator
Switches between indicated data and content