System Status Register 2

7
Bit
Name
0
1
40PE
1
0
2
SDMAPE
1
0
3
DARFPE
1
0
4
EPAKPE
1
0
5
SCSIP
1
0
7-6
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Address 60000000h
Byte Read Only
6
5
4
3
2
1
Function
Reserved, mask to zero when read
68040 Parity Error
A parity error was detected during a 68040 DRAM read
No 68040 Parity error since last read of System Status Register 2
SCSI DMA Parity Error
A parity error was detected during a SCSI DMA DRAM read
No SCSI DMA Parity error since last read of System Status Register 2
DARF64 Parity Error
A parity error was detected during a DARF64 DRAM read
No DARF64 Parity error since last read of System Status Register 2
EPAK Master Parity Error
A parity error was detected during a EPAK Master DRAM read
No EPAK Parity error since last read of System Status Register 2
SCSI Present
SCSI Controller present
SCSI Controller depopulated
Reserved, mask to zero when read
Extensible Single Board Computer/Controller User's Manual 65
Performance Computer
0
Reserved
40PE
SCSIPE
DARFPE
EPAKPE
SCSIP
Reserved