Environmental Specifications for Oracle Database Appliance X9-2 Series

Item
Oracle Database Appliance
X9-2S
Operating
5° C to 35° C (41° F to 95° F)
temperature
Nonoperating
-40° C to 70° C (-40° F to 158°
temperature
F)
Operating
10% to 90% relative humidity,
humidity
noncondensing
Nonoperating
Up to 93% relative humidity,
humidity
noncondensing
Operating
Up to 3,000 m* (9,840 ft);
altitude
maximum ambient temperature
is derated by 1° C per 300 m
above 900 m
* Except in China markets
where regulations might limit
installations to a maximum
altitude of 2,000 m (6,560 ft)
Nonoperating
Up to 12,000 m (39,370 ft)
altitude
Cooling
For more information on power
consumption, see Oracle
Server X9-2L
Acoustic noise 7.1 Bels A-weighted operating,
7.0 Bels A-weighted idling

Technical Support

How to obtain technical support for your appliance.
For technical support, go to:
https://support.oracle.com/portal/
Oracle Database Appliance
X9-2L
5° C to 35° C (41° F to 95° F)
-40° C to 70° C (-40° F to 158°
F)
10% to 90% relative humidity,
noncondensing
Up to 93% relative humidity,
non-condensing
Up to 3,000 m* (9,840 ft);
maximum ambient temperature
is derated by 1° C per 300 m
above 900 m
* Except in China where
regulations might limit
installations to a maximum
altitude of 2,000 m (6,560 ft)
Up to 12,000 m (39,370 ft)
For more information on power
consumption, see Oracle
Power Calculator
Server X9-2L
7.1 Bels A-weighted operating,
7.0 Bels A-weighted idling
Oracle Database Appliance
X9-2-HA
5° C to 35° C (41° F to 95° F)
-40° C to 70° C (-40° F to 158°
F)
10% to 90% relative humidity,
noncondensing
Up to 93% relative humidity,
non-condensing
Up to 3,000 m* (9,840 ft);
maximum ambient temperature
is derated by 1° C per 300 m
above 900 m
* Except in China where
regulations might limit
installations to a maximum
altitude of 2,000 m (6,560 ft)
Up to 12,000 m (39,370 ft)
Server node, see Oracle Server
Power Calculator
X9-2L
Power Calculator
Storage shelf
At maximum usage: 1553
BTU/h
At typical usage: 874
BTU/h
8.1 Bels A-weighted operating,
5.8 Bels A-weighted idling