"Physical Specifications" on page 15
■
"Environmental Specifications" on page 17
■
"Airflow Precautions" on page 18
■
Environmental Specifications
TABLE 1
Temperature, Humidity, Acoustic, and Elevation Specifications
Specification
Ambient temperature
Relative humidity
Altitude
Acoustic noise
TABLE 2
Description
Shock
Vibration
Related Information
SPARC S7-2 Server Safety and Compliance Guide
■
Operating
■ Maximum range: 41°F to 95°F (5°C to 35°C) up to 2,953
feet (900 meters)
■ Optimal: 69.8°F to 73.4°F (21°C to 23°C)
Note -
Maximum ambient operating temperature is derated by
1 degree C per 300 meters of elevation beyond 900 meters, up
to a maximum altitude of 3,000 meters.
■ 10% to 90% noncondensing, short term 23°F to 113°F (–
5°C to 55°C)
■ 5% to 90% noncondensing, but not to exceed 0.024 kg of
water per kg of dry air (0.053 lbs water/2.205 lbs dry air)
Up to 9,840 feet (3,000 meters)
Note -
In China markets, regulations may limit installations to
a maximum altitude of 6,562 feet (2,000 meters).
■ Maximum condition: 7.1 Bels A weighted
■ Idle condition: 7.0 Bels A weighted
Shock and Vibration Specifications
Operating
3.5 Gs, 11 ms half-sine
0.15 G (z-axis),
0.10 G (x-, y-axes), 5-
500Hz swept sine
Environmental Specifications
Nonoperating
–40°F to 154°F (–40°C to 68°C)
Up to 93% noncondensing 95°F (35°C)
maximum wet bulb
Maximum 39,370 feet (12,000 meters)
Not applicable
Nonoperating
Roll-off: 1.25-inch roll-off free fall, front to back
rolling directions
Threshold: 13-mm threshold height at 0.65 m/s
impact velocity
0.5 G (z-axis),
0.25 G (x-, y-axes), 5-500Hz swept sine