Environmental Specifications - Oracle SPARC T7-2 Installation Manual

Hide thumbs Also See for SPARC T7-2:
Table of Contents

Advertisement

Environmental Specifications

This topic includes these specifications that apply to both server configurations:
Temperature, humidity, and elevation
Shock and vibration
Acoustic
TABLE 1
Temperature, Humidity, and Elevation Specifications
Description
Operating
U.S.
Temperature
41 to 95°F
(maximum)
at 0 to 3000 ft
Relative humidity
10 to 90%
at 81°F
Altitude
0 to 9840 ft
Except in China markets where regulations might limit installations to a maximum altitude of 2km.
TABLE 2
Description
Shock
Vibration (vertical)
Vibration (horizontal)
TABLE 3
Description
Sound Power Level - LwAd (1 B = 10 dB)
Sound Pressure Level - LpAm (energy average of
4 bystander positions )
Related Information
SPARC T7-2 Server Safety and Compliance Guide
"Physical Specifications" on page 15
"Electrical Specifications" on page 16
"Environmental Specifications" on page 17
Nonoperating
Metric
U.S.
5 to 35°C
-40 to 149°F at 0
to 3000 ft
at 900m
10 to 90%
Up to 93%
at 27°C
at 100°F
0 m to 3000m
Up to 39,370 ft
Shock and Vibration Specifications
Operating
3G, 11 ms
0.15G
0.10G
Acoustic Specifications
Notes
Metric
-40 to 65°C at
Decrease in maximum temperature:
above 3000 ft. (900m), 1.8°F/1000 ft
900m
(1°C/300m)
Up to 93%
Maximum wet bulb noncondensing
at 38°C
Up to 12,000m
Notes
Half-sine
5 to 500 HZ swept-sine
MIN FAN SPEED
MAX FAN SPEED
7.7 B
8.9 B
67.8 dB
80.4 dB