When the instrument is in Sense Reverse Protection state, you should check
whether the polarities are connected reversely or not firstly. If yes, you can re-
open the output after the polarities connect correctly.
The voltage difference between output terminal and remote sense terminal of
each model is not the same. When the remote sense terminal is connected re-
versely, the maximum voltage will not exceed the sum of output terminal voltage
and the difference voltage.
4.6 Function Menu for Power Supply
The Function menu of the power supply includes the following:
Function
4.6.1 LIST Function
This series power supply supports a total of 10 List files (List01 to List10), each
of which can be set up to 200 steps. You need to edit the voltage/current value,
slope and time width of each step, or you can set repeat times (1 to 65535) for
When Sense is reversed or short-circuited, the voltage meter value is dis-
played as a positive/negative value close to 0, and abnormal high voltage
output does not occur, which can avoid damage to the DUT.
Function Menu for Power Supply
LIST
BATTERY
Road-Vehicles
SAS
Battery Emulator
Copyright © Itech Electronic Co., Ltd.
LIST program editing, file import/export, pro-
gram running (see
4.6.1 LIST
Battery charging and discharging testing
function (see
4.6.2 Battery Charging/Dis-
charging Test
Function).
Built-in waveform function (see
Waveform
Function).
PV simulation function (see
tovoltaic Curve Simulation Function
Battery simulation test function (see
Battery Simulation
Function).
Power Supply Function
Function).
4.6.3 Built-in
4.6.4 Solar Pho-
(SAS)).
4.6.5