Parameter
Setup Temperature
Coefficient
Read Back Temper-
ature Coefficient
Rise Time( no load
)
Rise Time( full load
)
Fall Time( no load )
Fall Time( full load )
Transient Response
Time
change from 20% to
90% of rated
current
Line Regulation
Load Regulation
Output protection
Remote Sense
Compensation
Voltage
External analog
(optional)
Other parameters:
Vrms
Voltage
Current
Voltage
Current
Voltage
Voltage
Voltage
Voltage
Voltage
Voltage
Current
Voltage
Current
OCP
OVP
Overpower
protection
current program
current monitor
voltage program
voltage monitor
Copyright © Itech Electronic Co., Ltd.
IT-M3906C-80-120
≤50ppm/℃
≤50ppm/℃
≤50ppm/℃
≤50ppm/℃
≤0.01% + 0.01%FS
≤0.05% + 0.05%FS
≤0.01% + 0.01%FS
≤0.05% + 0.05%FS
-125A or 125A
-6120W or 6120W
≤2V
External programming voltage -10V to 10V corre-
sponds to current -120A to 120A
Current -120A to 120A corresponds to external
monitoring voltage -10V to 10V
External programming voltage 0 to 80V Corre-
sponding voltage 0 to 10V
Voltage 0 to 80V corresponds to external monitor-
ing voltage 0 to 10V
Technical Specification
≤80mV
≤15ms
≤30ms
≤30ms
≤15ms
≤1ms
82V
183