Edit List Program
The following takes CC priority mode as an example to introduce the operation
of editing two test steps.
1. Press the composite keys [Shift]+[I-set] (Function) on the front panel to en-
2. Select 1. LIST: Off and press [Enter].
3. Rotate the knob to select Edit and press [Enter] to enter the editing
End
State
Save to
group
ter the function menu.
interface.
Copyright © Itech Electronic Co., Ltd.
Set the running state after the list program is run-
ning over.
Last
After the List program finishes run-
ning, the output is kept as the set-
ting in the last step, and the
working mode remains as the set-
ting in the List file.
None: No trigger signal output.
Tout: There is a trigger signal
output.
Normal
After the List program finishes run-
ning, the working mode and volt-
age/current output return to the
settings before the List running.
None: No trigger signal output.
Tout: There is a trigger signal
output.
OFF
After the List program finishes run-
ning, the output of the instrument
is turned off.
None: No trigger signal output.
Tout: There is a trigger signal
output.
Save the edited List program.