High Power Programmable DC Power Supply IT-M3900D Series User Manual Model: IT-M3900D Series Version: V2.1/5,2023...
Page 2
CAUTION sign until the in- pose. ITECH shall not be held liable Manual Part Number dicated conditions are for errors or for incidental or indirect fully understood and met.
Warranty ITECH warrants that the product will be free from defects in material and work- manship under normal use for a period of one (1) year from the date of delivery (except those described in the Limitation of Warranty below).
Failure to comply with these precautions or specific warn- ings elsewhere in this manual will constitute a default under safety standards of design, manufacture and intended use of the instrument. ITECH assumes no li- ability for the customer’s failure to comply with these precautions.
The IT-M3900D series is a single channel output programmable DC power sup- ply. The density structure design can effectively save rack space. Also with wide-range output design, can provide a wider range of voltage and current combinations within the specified power range.
Page 29
Cabinet installation This series instruments can be mounted on a standard 19-inch cabinet. ITECH has prepared a special bracket for the user as a mounting kit. – IT-E155A+IT-E155C: Select this mounting kit when mounting a 1U in- strument to an ITECH cabinet. Please refer to 《IT-E155 User Manual 》...
Page 36
Short circuit may cause severe accident. • Always use test cables provided by ITECH to connect the equip- ment. If test cables from other factories are used, please confirm the maximum current that the test cables can withstand.
• VCP: Virtual serial port. For Win7 system, you can download IT-M3900 VCP driver from ITECH official website or contact technical support engineer; for Win10 system, you do not need to install VCP driver. The operation steps to change the USB interface type in System Menu are as follows.
Page 42
Web Control: Enables the Web control to begin controlling the instrument. This page allows you to monitor and control the instrument; • Manual: Go to the ITECH official website and view or download the relevant documents. • Upload: Performs a system upgrade.
The instruments allow any combination of up to six simultaneous socket and telnet connections to be made. ITECH instruments have SCPI socket services, which can be used to send and receive SCPI commands, queries, and query responses. All commands must be terminated with a newline for the message to be parsed.
When you return power to the instrument, verify that the cooling fan is running. If not, please contact ITECH Technical Support. Leaving the instrument powered on with an inoperative cooling fan may result in damage to the instrument.
Page 73
Import via U disk The instrument supports importing the edited .csv format file (the template can be downloaded from ITECH official website or contact ITECH to obtain) through the USB interface on the front panel, and generating voltage or cur- rent values after parsing, and then outputting complex voltage or current waveforms according to the time width specified by the user.
Page 110
Analog in The setting for the voltage/current lower limit corresponds to Ch3 in the menu. (IT-M3900D series models do not need to be set) Analog quantity menu description When the analog quantity function is optionally equipped, the system menu dis- plays the analog quantity menu.
Page 111
Indicates the offset of channel 2. Set the parameters of channel 3 (lower limit channel). For the IT-M3900D series of unipolar power supplies, the voltage/current lower limit does not need to be specified. There- fore, the Ch3 parameters here do not need to be set.
For example, when there are multiple system upgrading package post- fixed with .itech in the root directory of your USB flash drive, you need to use a text editing tool to open the configuration file and specify the up- grade package name corresponding to the present upgrade operation.
Page 118
Info)) for selective upgrading based on the SN number in subse- quent upgrades. 3. If the upgrade fails, the interface will prompt Update fail. At this point, you cannot use the instrument. Please contact ITECH technical staff for treatment. Upgrade Operation •...
If there are still some problems, carefully read the Warranty and Limitation of Warranty in the preface of the manual. Confirm that your instrument complies with warranty service conditions. If after your warranty expires, ITECH offers re- pair services at competitive prices.
4006-025-000 for technical support and services. 7.4 Return for Repair If your instrument fails during the warranty period, ITECH will repair or replace it under the terms of your warranty. After your warranty expires, ITECH offers re- pair services at competitive prices. Also you can purchase an extended mainte- nance service contract that exceeds the standard warranty period.
Page 192
ITECH recommends that you retain the original shipping carton for return ship- ments and always insure shipments. To ship the unit to ITECH for service or repair: 1. Download the ITECH maintenance service application from our website, complete it and place it in the box with the instrument.
♦ Fuse Replacement A.1 Specifications of Red and Black Test Cables ITECH provides you with optional red and black test cables, which are sold indi- vidually and you can select for test. For specifications of ITECH test cables and maximum current values, refer to the table below.
If there are no fuse assembly on the instrument rear panel, it means that you can’t replace the fuse by yourself. Please contact the ITECH engineer on the condition of the same malfunction.