Parameter
Rise Time( no load
)
Rise Time( full load
)
Fall Time( no load )
Fall Time( full load )
Transient Response
Time
Line Regulation
Load Regulation
Output protection
Remote Sense
Compensation
Voltage
External analog
(optional)
Other parameters:
AC Input
Max. apparent
power
Max. input current
Max. efficiency
Voltage
Voltage
Voltage
Voltage
Voltage
Voltage
Current
Voltage
Current
OCP
OVP
Overpower protection
current program
current monitor
voltage program
voltage monitor
Voltage
Frequency
Copyright © Itech Electronic Co., Ltd.
Technical Specification
IT-M3905C-10-510
≤50ms
≤100ms
≤50ms
≤100ms
≤10ms
≤0.05% + 0.05%FS
≤0.05% + 0.05%FS
0.0035%*I + 0.05%FS
≤0.05% + 0.05%FS
-370A or 520A
10.5V
-3672W or 5202W
≤2V
External programming voltage -10V to
10V corresponds to current -510A to 510A
(effective range -360A to 510A)
Current -510A to 510A corresponds to ex-
ternal monitoring voltage -10V to 10V (ef-
fective range -360A to 510A)
External programming voltage 0 to 10V
Corresponding voltage 0 to 10V
Voltage 0 to 10V corresponds to external
monitoring voltage 0 to 10V
3phase 110V~520V
Single phase 85V~300V
50/60Hz
5.55kVA
12.5Aac
92%
178