Parameter
Read Back
Accuracy
Voltage ripple
Setup Temperature
Coefficient
Read Back Temper-
ature Coefficient
Rise Time( no load )
Rise Time( full load )
Fall Time( no load )
Fall Time( full load )
Dynamic response
time
change from 20% to
90% of rated current
Line Regulation
Load Regulation
Output protection
Remote Sense
Compensation
Voltage
External analog
(optional)
Voltage
Current
Power
Vp-p
Vrms
Voltage
Current
Voltage
Current
Voltage
Voltage
Voltage
Voltage
Voltage
Voltage
Current
Voltage
Current
OCP
OVP
Overpower
protection
current program
Current -60A to 60A corresponds to external moni-
current monitor
voltage program
voltage monitor
Copyright © Itech Electronic Co., Ltd.
IT-M3906C-300-60
≤0.03% + 0.03%FS
≤0.1% + 0.1%FS
≤0.5% + 0.5%FS
≤300mVpp
≤100mV
≤50ppm/℃
≤50ppm/℃
≤50ppm/℃
≤50ppm/℃
≤0.01% + 0.01%FS
≤0.05% + 0.05%FS
≤0.01% + 0.01%FS
≤0.05% + 0.05%FS
-63A or 63A
-6120W or 6120W
≤3V
External programming voltage -10V to 10V corre-
sponds to current -60A to 60A
toring voltage -10V to 10V
External programming voltage 0 to 300V Corre-
sponding voltage 0 to 10V
Voltage 0 to 300V corresponds to external moni-
toring voltage 0 to 10V
Technical Specification
≤15ms
≤30ms
≤30ms
≤15ms
≤1ms
303V
188