Kohler Decision-Maker 1 Manual page 12

Industrial generator sets
Table of Contents

Advertisement

Grounding electrical equipment.
Hazardous
voltage
can
severe injury or death. Electrocution
is possible whenever electricity is
present. Ensure you comply with all
applicable
codes
and
Electrically ground the generator set,
transfer switch, and related equipment
and electrical circuits. Turn off the main
circuit breakers of all power sources
before servicing the equipment. Never
contact electrical leads or appliances
when standing in water or on wet
ground because these conditions
increase the risk of electrocution.
High voltage test.
voltage can cause severe injury or
death. Follow the instructions of the
test equipment manufacturer when
performing high-voltage tests on the
rotor or stator.
An improper test
procedure can damage equipment or
lead to generator set failure.
Testing the photo transistor circuit
board.
Hazardous voltage can
cause severe injury or death. When
the end cover is removed, do not
expose the photo transistor circuit
board mounted on the generator set
end bracket to any external light
source, as exposure to light causes
high voltage. Keep foreign sources of
light away from the photo transistor
circuit board during testing.
black electrical tape over the LED on
the circuit board before starting the
generator set.
Installing
the
photo
circuit board.
Hazardous voltage
can cause severe injury or death.
Ensure that the foil side of the photo
transistor circuit board, the end of the
shaft, and the threaded holes are clean
and free of metal particles and chips.
Metal debris may short-circuit
photo transistor circuit board and cause
hazardous voltage in the generator set.
Do not reconnect the generator set to
the load until the AC voltmeter shows
the correct output.
12
Safety Precautions and Instructions
Welding on the generator set. Can
cause
cause severe electrical equipment
damage.
generator set perform the following
steps: (1) Remove the battery cables,
standards.
negative (--) lead first. (2) Disconnect
all engine electronic control module
(ECM) connectors. (3) Disconnect all
generator set controller and voltage
regulator circuit board connectors.
(4) Disconnect the engine battery-
charging
(5) Attach the weld ground connection
close to the weld location.
Installing
Hazardous
Hazardous
severe
ungrounded battery
cause electrical shock. Connect the
battery charger enclosure to the ground
of a permanent wiring system. As an
alternative,
grounding
conductors and connect it to the
equipment grounding terminal or the
lead on the battery charger. Install the
battery charger as prescribed in the
equipment manual. Install the battery
charger in compliance with local codes
and ordinances.
Connecting the battery and the
battery charger. Hazardous voltage
can cause severe injury or death.
Place
Reconnect
positive to positive and negative to
negative, to avoid electrical shock and
damage to the battery charger and
battery(ies).
transistor
electrician install the battery(ies).
Short
voltage/current can cause severe
injury or death. Short circuits can
cause bodily injury and/or equipment
damage.
the
connections with tools or jewelry while
making
Remove all jewelry before servicing the
equipment.
Engine block heater.
voltage can cause severe injury or
death. The engine block heater can
cause electrical shock. Remove the
engine block heater plug from the
electrical outlet before working on the
block heater electrical connections.
Before welding on the
alternator
connections.
the
battery
charger.
voltage
can
cause
injury
or
death.
An
charger may
install
an
equipment
conductor
with
circuit
the
battery
correctly,
Have
a
qualified
circuits.
Hazardous
Do not contact electrical
adjustments
or
repairs.
Hazardous
Electrical backfeed to the utility.
Hazardous backfeed voltage can
cause severe injury or death. Install
a transfer switch in standby power
installations to prevent the connection
of standby and other sources of power.
Electrical
backfeed
into
electrical system can cause severe
injury or death to utility personnel
working on power lines.
Testing
live
electrical
Hazardous voltage or current can
cause severe injury or death. Have
trained and qualified personnel take
diagnostic
measurements
circuits.
Use adequately rated test
equipment with electrically insulated
probes and follow the instructions of the
test equipment manufacturer when
performing voltage tests. Observe the
following precautions when performing
voltage tests: (1) Remove all jewelry.
(2) Stand on a dry, approved electrically
insulated mat. (3) Do not touch the
enclosure or components inside the
enclosure.
(4) Be prepared for the
system to operate automatically.
(600 volts and under)
WARNING
Airborne particles.
Can
cause
severe
blindness.
Wear protective goggles and clothing
when using power tools, hand tools,
or compressed air.
Servicing the generator set when it
is operating. Exposed moving parts
can cause severe injury or death.
Keep hands, feet, hair, clothing, and
test leads away from the belts and
pulleys when the generator set is
running. Replace guards, screens, and
covers before operating the generator
set.
TP-6356 4/12
a
utility
circuits.
of
live
injury
or

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents