FUSING
7.6
THERMOFUSE REPLACEMENT
[E]
1. Remove the fusing unit (see Fusing Unit Removal).
2. Remove the fusing unit cover [A] (2 shoulder screws, 1 screw).
3. Lower the fusing exit assembly [B].
4. Remove the thermofuse harness lead [C] (1 screw) from the front fusing
lamp terminal and disconnect the thermofuse harness from the fusing
harness [D].
5. Remove the thermofuse holder [E] (1 screw) then remove the thermofuse
(2 plate clamps).
[A]
[D]
5-74
12 February 1992
[C]
[B]