8. If the transfer corona current is out of the adjustment standard, do the
following steps.
9. Enter "162" (T-CH PWM) by using the number keys, then press the enter
key.
10. Change the PWM value displayed in the three digit indicator by using the
number keys as follows:
To increase the corona current (absolute value): increase the PWM value.
To decrease the corona current (absolute value): decrease the PWM
value.
NOTE: You may use the following rule as reference:
Changing the PWM value by 16 will change the transfer corona
current by about 1µA.
11. Press the enter key.
12. Repeat steps 4 to 11 until the proper transfer corona current is obtained.
13. Turn off the main switch.
5-22
10 July 1992

Advertisement