PAPER FEED
[B]
(4) Lower Paper Feed Clutch
1. Take the high voltage cables off the hooks on the exhaust blower housing.
2. Remove the exhaust blower assembly [A] (2 screws and 1 connector).
3. Move the high voltage supply board assembly [B] from the copier base
plate (1 screw, 2 wire saddles for bias cable).
4. Remove the stopper bracket [B] (1 screw).
5. Remove the lower paper feed clutch [C] (1 E-ring, 1 connector, 1 wire
saddle).
NOTE: When reinstalling the clutch, make sure that the clutch stopper pin [D]
engages with the groove of the stopper bracket.
[A]
5-42
[C]
[D]
[B]