Figure 4-21 Reduced Charge Rate Setup Screens - Webasto PosiCharge SVS100N Operation And Maintenance Manual

Gse intelligent fast charging systems
Table of Contents

Advertisement

4.12.8 Reduced Rate Charge Feature Configuration
The charger can be configured to allow a window of time per day to reduce the charge rate to
the connected battery. This is useful if there is a period of time when the batteries left on the
charger should charge at a slower rate to prevent heating issues. At certain installations the
batteries are opportunity charged at their maximum rate but at a cost of heat generated in the
battery. If it is known that during certain periods the battery will not need to charge at maximum
rate then the power delivered can be backed off by a programmable amount.
When this feature is enabled and the start and stop times are encountered, the maximum
charge rate of the battery is limited to the charge rate programmed in this feature. For example,
if a battery is connected to the charger at 11:00am, the battery capacity is 1000 amp hours, and
its start rate is 50amps/100 amp-hours, the battery will normally start charging at 500amps. If
the reduced rate feature is set to be enabled from 10:00am to 12:00pm, and the limit is
25amps/100 amp-hours, then as soon as the clock reaches 10:00 am, the current will drop from
500 to 250amps. The charging will continue with this rate limit until the window is closed at
12:00pm when the current limit returns to 500 amps.
4.12.8.1
Setting the Reduced Rate Charge Configuration
From the "Reduced Charge Rate Setup" screen, press <enter> to display the Reduced Rate
Enable status. Press <enter> again to enable editing. Use the <up> and <down> buttons to
toggle between "ON" and "OFF" and press <enter> to accept edits. Use the <select> button to
cycle through the remaining screens. Edit the time and current limit parameters using the
<enter>, <up>, and <down> buttons. Once editing is complete, use the <clear> button
repeatedly to return to the top-level screen.
Reduced Charge Rate
Setup
Reduced Rate Enable:
CLEAR
OFF
Reduced Chr Start time
00:00
Reduced Chr End time
05:00
Reduced Charge Cur Lim
020 Amps/100Amphrs
12876-W-03-01
ENTER
SELECT
SELECT
SELECT
SELECT

Figure 4-21 Reduced Charge Rate Setup Screens

Charger Configuration
CLEAR
ENTER
Reduced Rate Enable:
ON
SELECT
ENTER
Press ENTER and use the UP and
DOWN arrow buttons to set the
parameter to the appropriate value.
ENTER
Press ENTER again to accept the
selection made.
Press CLEAR to retain the original
ENTER
value
28
SVS100N Operation/Maintenance Manual
Webasto Charging Systems, Inc.
CLEAR