4.12.1 Battle Mode Setup
Battle Mode Setup
24V Start Current
CLEAR
100 A
24V Target Voltage
2.40 V/cell
24V Finish Current
030 A
36V Start Current
100 A
24V Start Current
100 A
24V Target Voltage
2.40 V/cell
24V Finish Current
030 A
Default Batt Temp
095 F
4.12.2 Clear Backup Memory
The clear battery backed RAM Data screens (See Figure 4-15) allow the user to clear the
battery-backed charger memory. This memory contains the charge event log, the fault event
log, and the charger configuration parameters.
In the "Clear RAM Data?" screen, use the UP and DOWN arrows to choose "OK" or "Cancel".
Press ENTER while "OK" is displayed to clear the memory; Press ENTER while "CANCEL" is
displayed or press "CLEAR" to cancel clearing the memory.
12876-W-03-01
ENTER
SELECT
SELECT
SELECT
SELECT
SELECT
SELECT
SELECT
SELECT
Figure 4-14 Clear Backup Memory Menu
SVS100N Operation/Maintenance Manual
Charger Configuration
CLEAR
ENTER
Press ENTER and use the UP and
DOWN arrow buttons to set the
parameter to the appropriate value.
ENTER
Press ENTER again to accept the
selection made.
Press CLEAR to retain the original
ENTER
value
ENTER
ENTER
ENTER
ENTER
ENTER
22
Webasto Charging Systems, Inc.