Technical Specifications

6
Model
Number
Number
of Phases
SVS100N
3
Part number: 11287
12 to 48V:
250A+
72 to 80V:
125A
12 to 40 cells
Flooded or Sealed battery
Up to 2500 Ah
12876-W-03-01

Table 5-2 Warning Codes

BMID Config
Early Chrg Term
BMID TmpSnsor Fail
Failed Backup Battery
Maximum Output Current Not
Set
Air System Failure
INPUT
Freq
Voltage
Hz
50/60
Meaning
BMID data invalid, needs
configuration
Charge terminated
unexpectedly
BMID temp sensor out of valid
range
Battery Backed Up Ram Has
Lost Data
Maximum Output Current Not
Set
No Air Pressure has been
detected.
Current
AC
AMPS
450
15
38
SVS100N Operation/Maintenance Manual
OUTPUT
Voltage
Rating
DC
kW
16-120
10.0
Webasto Charging Systems, Inc.
Current
AMPS
250