Fault/Warning Log
CLEAR
Fault Event 1
12:29 02/06/07
Fault Event 2
CLEAR
12:20 02/06/07
Fault Event 3
23:23 02/04/07
Fault Event
Log entry blank
CLEAR
Log entry blank

Charge Event Log

4.9
The charge event log data screens (see Figure 4-10) allow the user to review the data from the
last 250 fast charge or equalization events performed by the charger. These data are stored in
the charger and are preserved even if power is removed from the charger.
1. Event ID screen - Shows the active (most recent) charge event. Using the UP and DOWN
arrow keys the user may scroll through the last 250 charge events. For each charge event,
the BMID number will be displayed to help the user locate a particular charge event. Once
the desired event is displayed, press ENTER to open the log for that event. Press CLEAR
at any point in the log to return to the Event ID screen.
2. Battery state screen - Shows the beginning and ending voltage, beginning and ending
current, and beginning and ending states of charge (SOC) for the selected charge event.
3. Charge date screen - Shows the date and time recorded at the beginning and end of the
selected charge event.
4. kWhrs Returned – Shows the cumulative kWhrs returned to the battery during the selected
charge event.
5. Battery Temperature Screen - Shows the battery temperature at the beginning and end
points of the selected charge event.
6. Charge Type- Shows the type of charge that was in progress during the selected charge
event.
7. Cumulative charge data screen - Shows the elapsed time and cumulative Ah returned to the
battery during the selected charge event.
8. Charge Start Code – Numerical code that tells the user the reason of the start of a charge
during the selected charge event.
12876-W-03-01
ENTER
1
There are 50
Fault events
in a log
n
ENTER

Figure 4-9 Fault/Warning Log Data Screens

SVS100N Operation/Maintenance Manual
To top level screens
CLEAR
ENTER
Fault Code: 119
BMID TempSensr Fail
Cleared
12:30 02/06/07
Idle
at time of fault
15
2
3
4
CLEAR
Webasto Charging Systems, Inc.