Programming Menu Entry
1. To enter the programming modes from the main menu, press ENTER when the desired
programming mode is SELECTED.
2. You will be prompted enter the access code. Contact your Authorized PosiCharge
for the code, or call customer service at
3. Once the access code has been accepted the screen will change and hold for five (5)
seconds to indicate you have entered programming mode.
4. If programming mode is entered while the charger is charging, the user will be prompted to
Cancel (Default) terminating the charge or to OK the programming mode. Use the UP and
DOWN arrow keys to toggle between OK and Cancel, and press ENTER to choose the
desired option or CLEAR to Cancel. If the charger is not charging, this step will be skipped.
5. After authorization, the selected programming mode is now active.

4.12 Charger Configuration

The charger stores configuration information for eight sets of parameters. Each of these,
except Charge Algorithms, may be edited by the user from the charger configuration menu (see
Figure 4-13). These data are stored in the charger and are preserved even if power is removed
from the charger.
1. Battle Mode Setup allows the user to over-ride the battery charging settings for start
current, target voltage, finish current and battery temperature. The vehicle must be
disconnected and reconnected to the charger for the Battle mode charger settings to be
applied.
2. Clear Backup Memory Data allows the user to clear the memory in the charger, which
contains charge events, fault events, and charger configuration parameters.
3. External Light Configuration allows the user to set two modes of operation: Selector Mode
and 3 external lights can be configured to monitor any of the 5 following states of Charger
operation: Connected and Stop Charging, Connected and Charging, Connected and
Equalizing, Port available and Fault or Warning. This feature is only applicable in systems
where external lights have been installed and connected to the charger.
4. EQ Button Action Configuration allows the user to configure the behavior of the EQ
button. The default setting is "Always Active.
5. Auto EQ allows the user to turn the auto EQ feature on or off. The default setting is "ON".
6. Fast Charge SOC Limit allows the user to set the State of Charge limit for fast charging.
The default setting is "100%".
7. Full Charge Setup allows the user to customize the behavior of the charger to exceed the
fast charge SOC limit. The default setting is "ON", start time default setting is "02:00" end
time default setting is "06:00" military time.
8. Reduced Charge Rate Setup allows the user to program the charger for a reduced charge
rate when a high rate of charge would result in excessive battery temperatures. The default
setting is "OFF".
9. Temperature Readout Selection allows the user to select Fahrenheit or Celsius for the
temperature display. The default setting is "Fahrenheit".
12876-W-03-01