VHR Cold Water Connection-
DH6000-VHR, DH6000T-VHR
COLD
WATER
MINIMUM/MAXIMUM INCOMING
TEMPERATURE
55-75ºF / 13-24ºC
WATER HARDNESS OF 3 GRAINS/US GAL - 0.83 IMP GAL - 5.3mg/L OR LESS.
INSTALL A ¾" OR LARGER FULL PORTSHUT-OFF VALVE IN THE WATER
Hot Water Connection- DH6000, DH6000T
SUPPLY LINE AS CLOSE TO THE DISHWASHER AS POSSIBLE FOR SERVICING.
HOT
WATER
MINIMUM/MAXIMUM INCOMING
TEMPERATURE
110-140ºF/43-60ºC
WATER HARDNESS OF 3 GRAINS/US GAL - 0.83 IMP GAL - 5.3mg/L OR LESS.
CAUTION:
INSTALL A ¾" OR LARGER SHUT-OFF FULL PORT VALVE IN THE WATER
plumber must thoroughly flush debris from the water supply line before
SUPPLY LINE AS CLOSE TO THE DISHWASHER AS POSSIBLE FOR SERVICING.
connecting it to the dishwasher. Damage caused by improper installation is not
covered by the limited warranty.
WATER HARDNESS OF 3 GRAINS/US GAL - 0.83 IMP GAL - 5.3mg/L OR LESS.
INSTALL A ¾" OR LARGER FULL PORT SHUT-OFF VALVE IN THE WATER
SUPPLY LINE AS CLOSE TO THE DISHWASHER AS POSSIBLE FOR SERVICING.
MINIMUM 3/4" NPT COLD WATER SUPPLY
MINIMUM INCOMING
SUPPLY FLOWING PRESSURE
46-50 PSI
MINIMUM 3/4" NPT HOT WATER SUPPLY
MINIMUM INCOMING
SUPPLY FLOWING PRESSURE
45 PSI / 310 kPa
To prevent damage to the dishwasher supply valves, the installing
MINIMUM/MAXIMUM
OPERATING FLOWING PRESSURE
18-20 PSI
MINIMUM/MAXIMUM
OPERATING FLOWING PRESSURE
18-20 PSI / 124-138 kPa
Installation
5