ISLAND CONFIGURATION LAYOUT - EXPLODED VIEW / INSTALLATION OVERVIEW
ISLAND CONFIGURATION LAYOUT - EXPLODED VIEW / INSTALLATION OVERVIEW
Below illustration provides a perspective view of the food bar island layout.
Follow the six (6) step-by-step installation procedure as sequentially listed below.
See the next page for a perspective view of the food bar in-line layout.
Next page also has views of certain 'swappable' cases (applicable to both islands and in-line layouts).
2. Napkin/Utensil/Trash
End Cap: No Hookups
Model CB6T.4764 (Shown) and
DP610RE or DP1016RGE
(Glycol-Based Unit)
3. Cold Bar: Hook Up
Refrigeration Lines/Drain Lines/
Electrical From CB2CE.
Model DP1016R.4764 (Shown),
DP812R.4764, DP812RG.4764,
DP610R.4764, DP610RG.4764
and DP58R.4764
6. Container Cabinet: No Hookups.
Model CB2C.4764 (Without Main
Electrical Panel)
1. Hot Bar: Hook Up Water Inlet Drain
Electrical From CB2CE.
Model DP1016H.4764 (Shown),
DP1016HO, DP812H.4764,
DP812HO.4764, DP610H.4764,
DP610HO.4764 and DP58H.4764
5
5. Container Cabinet. Hook
Up Incoming Power.
Model CB2CE.4764 (With
Main Electrical Panel)
4. Soup Bar: Hook Up
Water Inlet Drain (2 Places).
Hook Up Electrical From
CB2CE. Model DP647Q.4764.
Need help?