Note:
• The self RAM check completes in approximately 2.5 minutes.
• When you start the self RAM check, the drive will detect oFA00 [Option Not Compatible with Port].
1.
Set DIP switch S1 as shown in
Note:
Use non-conductive tweezers or a tool with a tip width of approximately 0.5 mm (0.02 in) to set DIP switch S1.
2.
Apply power to the option.
This will start the self RAM check.
3.
Look at the LEDs on the option to see the status of the self RAM check.
Refer to
Table 10.2
Self RAM Check Status
Checking
Successful termination
Abnormal termination
11

European Standards

The CE mark indicates compliance with European safety and environmental regulations.
European standards include the Machinery Directive for machine manufacturers, the Low Voltage Directive for
electronics manufacturers, and the EMC Directive for controlling noise.
It is required for engaging in business and commerce in Europe.
This option displays the CE mark based on the EMC Directive.
EMC Directive: 2014/30/EU
Drives used in combination with this option and devices used in combination with the drive must also be CE
certified and display the CE mark.
When using drives displaying the CE mark in combination with other devices, it is ultimately the responsibility of
the user to ensure compliance with CE standards. Verify that conditions meet European standards after setting up
the device.

EMC Directive Compliance

This option is tested according to European standard EN 61800- 3:2004/A1:2012 and complies with the EMC
Directive. The CE marking is declared based on the harmonized standards.

Option Installation

Verify the following installation conditions to make sure that other devices and machinery used with this option
and drive also comply with the EMC Directive:
1.
Use dedicated shielded cable for the option and external device (encoder, I/O device, Controller), or run
the wiring through a metal conduit.
YASKAWA SIEP C730600 0KA PROFINET Technical Manual
Figure
10.1.
Figure 10.1 DIP Switch S1 Settings for the Self RAM Check
for more information.
Table 10.2 LED States during Self RAM Check
Figure 11.1 CE Mark
LED States
MS
Lit in green
Lit in green
Lit in red
11 European Standards
NS
OFF
Lit in green
Lit in red