NOTICE
Damage to Equipment. Make sure that all connections are correct after you install the drive and connecting
peripheral devices. Incorrect connections can cause damage to the option.
◆
Settings for DIP Switch S1
Use the DIP switch S1 on the option to select the communication protocol.
Use non-conductive tweezers or a tool with a tip width of approximately 0.5 mm (0.02 in) to set DIP switch S1.
Figure 5.1
shows the default settings for DIP switch S1.
When you use PROFINET, set DIP switch S1 as shown in
Note:
If you set the DIP switch for a different protocol, it will erase all user-entered data from the JOHB-SMP3, including the Station Name.
◆
Procedures to Install and Wire Options on a Drive
Procedures to install and wire the option are different for different drive models.
Refer to
Table 5.1
to check the procedures to install and wire the option on a drive.
Product Series
A1000
U1000
Z1000U
Z1000
GA500
GA700
GA800
CR700
HV600
FP605
*1
To install the option on GA500 drives, use the option mounting kit (JOHB-GA50) and manual.
■
Procedure A
This section shows the procedure to install and wire the option on a 1000-series drive.
Prepare the Drive for the Option
Correctly wire the drive as specified by the manual packaged with the drive. Make sure that the drive functions
correctly. Refer to the drive manuals for more information.
YASKAWA SIEP C730600 0KA PROFINET Technical Manual
Figure 5.1 Default Settings for DIP Switch S1
Figure 5.2 PROFINET Settings for DIP Switch S1
Table 5.1 Procedures to Install and Wire Options on a Drive
Procedures to Install and Wire Options on a Drive
Figure
5.2.
Procedure A
Procedure A
Procedure A
Procedure B
*1
Procedure C
Procedure C
Procedure C
Procedure D
Procedure D
5 Installation Procedure
Page
13
13
13
15
-
17
17
17
18
18
13