CHANGING PARAMETERS

1. Use selection button to select the parameters required.
The yellow LED lights up.
2. Set parameter value with rotary controller.
The value set is shown in LED display 19.
3

CALLING / CHANGING / SAVING PROGRAMS 1-4

1. Select the program you want by pressing the corresponding program button.
2x
2. Set new parameters (electrostatic, air quantity) (see 2).
3. Press the program button required for around 2 seconds until the LED fl ashes
2x
rapidly.
The program is saved with new parameters and can be called up again at any time
at the touch of a button!
4
CALLING / CHANGING / SAVING PROGRAMS 5-50
1. Press additional programs button.
2. Set program number with rotary controller.
The program number is shown in the LED display.
3. Set new parameters (see 2).
4. Press additional program button for around 2 seconds.
The changed parameters are saved.
5. The program number is shown fl ashing in the LED display.
6. Set program number required with rotary controller.
(Only necessary if the parameters are to be saved under another program number.)
7. Press additional program button for around 2 seconds.
8. LED display fl ashes quickly.
Program is saved with new parameters!