Setting The Powder Feed Quantity - WAGNER Prima Sprint Airfluid Translation Of The Original Operating Manual

Manual powder system
Table of Contents

Advertisement

VERSION 07/2009
OPERATING MANUAL
6.5.2

SETTING THE POWDER FEED QUANTITY

37
36
33
P_01118
When the control unit is in the ready position, the circular light strip 33 shows the set point
as a dot and when powder feeding is switched on it shows the actual value as a bar. The
powder quantity setting as % refers to the percentage distribution between the different
air types.
Example:
A powder quantity of 75% means that 75% of the overall air quantity is fed to the feed air
and 25% to the dosage air. The higher the proportion of feed air, the greater the powder
quantity for a given overall air quantity.
ORDER NUMBER DOC 2305835
EP G
SPR INT
19
24
EP G
SPR INT
Procedure:
1. Press the "powder quantity" button 36 to adjust the
powder quantity. The yellow LED 37 indicates that the
powder quantity is selected.
2. The powder quantity can now be adjusted using the
Universal rotary controller 24 between 0% - 100%
with a resolution of 1%. The value is shown in the LED
display 19.
Prima
Sprint.