VERSION 07/2009
OPERATING MANUAL
6.2.4
ADJUSTING FLUIDIZATION (60L CONTAINER WITH VIBRATOR TABLE)
Dust development!
Danger of poisoning.
Danger due to escaping dust, contamination of device and device
components.
SIHI_05058_ENG
1
P_01151
ORDER NUMBER DOC 2305835
The powder container may only be filled to the halfway mark,
because fluidizing increases the volume of powder.
2
WARNING
Procedure:
1. Open the lid and fi ll the powder container 1
halfway with powder.
2. Switch on the control unit.
3. Set the parameter "vibrator motor control" on
the control unit to approx. 4 min., so that fl uid air
for this length of time is activated (see operating
manual "EPG Sprint control unit").
4. Actuate the trigger of the spray gun for a short
time and release it.
5. Adjust the fl uid air at the throttle 2 until
fl uidization is recognizable.
Hint:
The amount of fl uid air depends on the
characteristics of the powder. Avoid a build up of
powder dust (too much fl uid air) in the powder
container!
6. Close the powder container 1 and check
whether the exhaust air hose is leading in the
direction of the ventilation system of the powder
coating booth.
Prima