Mounting The C4-Vl 150/300/500 S Gun Extension - WAGNER Prima Sprint Airfluid Translation Of The Original Operating Manual

Manual powder system
Table of Contents

Advertisement

VERSION 07/2009
OPERATING MANUAL
7.2.6

MOUNTING THE C4-VL 150/300/500 S GUN EXTENSION

Exploding dust/air mixture!
Danger to life from flying parts and burns.
SIHI_05041_ENG
Hint:
The gun must be thoroughly cleaned before installing the gun extension.
We recommend to use a new spray gun.
Procedure:
1. Unscrew the outer nut 1 from the spray gun housing 5.
2. Pull the fan spray nozzle 2 off the electrode holder 3.
3. Carefully pull the electrode holder 3 out of the spray gun housing 5.
Hint:
Do not damage the electrode holder 3, when pulling out.
4. Remove powder residue from the parts removed and from the spray gun.
ORDER NUMBER DOC 2305835
The inside coating of hollow bodies and/or in narrow spaces is
forbidden in accordance with BGI 764.
P_00933
3
2
1
P_00591
DANGER
5
Prima
Sprint.
76