Interrupting The Coating Process; Airfluid Version - WAGNER Prima Sprint Airfluid Translation Of The Original Operating Manual

Manual powder system
Table of Contents

Advertisement

VERSION 07/2009
OPERATING MANUAL
6.7

INTERRUPTING THE COATING PROCESS

6.7.1

AIRFLUID VERSION

Danger of clogging the fluid disk!
Danger of blockage.
Before the control unit is deactivated, the feed unit must be pulled out of the powder
container.
SIHI_05026_ENG
Powder residues!
Danger of equipment damage.
At every work interruption, blow through the spray gun and the powder feed
components and clean from any powder residues.
SIHI_05027_ENG
EP G
P_01137
ORDER NUMBER DOC 2305835
CAUTION
CAUTION
17
SPR INT
Procedure:
1. Release the trigger on the spray gun.
The high-voltage and the powder feed are
deactivated.
2. Lift the feed unit up underneath the injector, lift it
out of the container and swivel it to the right side,
so that no more powder is conveyed.
3. Guide the gun into the spray booth and start the
purge function by pressing the "rinse" button 17.
The injector and hoses are purged.
4. Now the control unit can be switched off.
Prima
Sprint.
56