OPERATING MANUAL
7.1

PERIODICALLY CHECK AND CLEAN THE MANUAL POWDER SYSTEM

7.1.1

AIRFLUID VERSION

EP G
P_01137
5
4
2
1
P_01139
ORDER NUMBER DOC 2305835
17
SPR INT
6
3
Procedure:
1. Release the trigger on the spray gun.
The high-voltage and the powder feed are
deactivated.
2. Lift the feed unit 1 up underneath the suction
connector 2, lift it out of the container and swivel
it to the right side, so that no more powder is
conveyed.
3. Guide the gun into the spray booth and start the
purge function by pressing the "rinse" button 17.
The injector and hoses are purged.
4. Switch off the control unit.
5. Release the outer nut on powder feed hose 3 and
disconnect powder feed hose 3 from injector 4.
6. Disconnect powder feed hose 5 (red) from injector
4.
7. Disconnect dosage air hose 6 (blue) from injector 4.
8. Pull the fl uid air hose (black) off the suction
connector 2.
9. Pull the injector 4 out of the feed unit 1.
10. Check the injector 4 for wear and replace worn parts
if necessary.
The wear and spare parts can be found in the
Operating manual of the powder injector.
11. Pull feed unit 1 out of the holder arm.
12. Blow out the suction tube of the feed unit 1
thoroughly and rub it clean with a dry cloth.
13. Check whether the fl uid disk on the bottom of the
feed unit is blocked and replace if necessary.