Switching The Gun Types - WAGNER Prima Sprint Airfluid Translation Of The Original Operating Manual

Manual powder system
Table of Contents

Advertisement

VERSION 07/2009
OPERATING MANUAL
9.4.2

SWITCHING THE GUN TYPES

Hint:
Clean thoroughly the powder residues from all powder-conveying parts, before changing
to another gun type.
P_01185
Procedure:
(For example: switching from Corona to Tribo)
1. Switch off control unit with switch 1 on rear.
2. Change the coating powder from Corona to Tribo.
3. Disconnect the hose 2 (black, atomizing air) from the Corona gun and connect it to the
Tribo gun (Tribo air).
4. Disconnect the powder feed hose of the Corona spray gun from the powder injector
and connect the Tribo gun hose on the powder injector.
5. Set the switch C on the switchbox to Tribo.