Technical Data - WAGNER Prima Sprint Airfluid Translation Of The Original Operating Manual

Manual powder system
Table of Contents

Advertisement

VERSION 07/2009
OPERATING MANUAL
4.4

TECHNICAL DATA

Dimensions:
Height
Width
Depth
Weight
Max. box size
Max. fi lling weight of box
Electrical:
Mains (AC)
Frequency
Maximum power
Output voltage
Output current
Corona current limitation
Tribo current limitation
Protection class
Pneumatic:
Compressed air connection
Connection hose diameter
Pressure range input air
Air quantity
Sum of feed and dosage air
Gun air
Wagner injector type
Compressed air quality
as per ISO 8573.1
Outgoing air containing oil!
Risk of poisoning if inhaled
SIHI_05034_ENG
ORDER NUMBER DOC 2305835
1120 mm; 44.10 inches
595 mm; 23.43 inches
740 mm; 29.13 inches
approx. 38 kg; 83.77 lbs
420x420x400 mm; 16.54x16.54x15.75 inches
30 kg; 66.14 lbs
85 VAC-250 VAC
47 Hz-440 Hz
40 W
max. 22 Vpp
max. 0.9 A
5 µA-120 µA (adjustable)
higher than 12 µA
(ATEX: switch the unit off )
IP 64
G1/4"
18.5 x 12.5 mm
0.6-0.8 MPa; 6-8 bar; 87-116 psi
max. 20 m³/h; 706.2 cf/h
2-12 m³/h; 70.6-423.7 cf/h
0.05-4.5 m³/h; 1.765-158.9 cf/h
PI-F1, HiCoat ED-Pump F
3.5.2
Provide water-free and oil-free compressed air (quality standard
3.5.2 as per ISO 8573.1) 3.5.2 = 5 μm / +7°C; 44.6°F / 5mg/m³.
WARNING
Prima
Sprint.