Functional Principle, Technical Data
SC2500 controller
RAM
Supply voltage
Current consumption
Digital interfaces
Connection
Installation
Temperature range
Shock (DIN EN 60068-2-27)
Vibration (DIN EN 60068-2-6)
Protection class
Material
Weight

Control and indicator elements

1) Max. permissible operating temperature with 0.7 m/s air blow
2) Connection via Processing Unit interface module
3.3
Control and Indicator Elements
Each of the two cameras has two LEDs for status indication on the rear side.
1
2
1
LED 1
Orange
Flashing orange
2
LED 2
Green
Flashing green
4 x fast flashing
Fig. 3 LED indicators of camera
surfaceCONTROL 3D SC2500 / SC2510
4 x Gigabit Ethernet (GigE Vision / GenICam) / USB 2.0 (sensor control) /
Storage
1
Operation
2 LEDs for storage and power; 4 LEDs for COM1 TX/RX and COM2 TX/RX
Ethernet connection available
Ethernet data traffic
Power supply to the camera
Boot process is running
Transmission error
16 GB
9 ... 36 V DC
3 ... 12.4 A
2
PROFINET
/ EtherCAT
4-pin supply terminal strip, 4 x Ethernet
Mounting holes, DIN rail mounting kit
-40 ... 85 °C (-40 ... 185 °F)
-10 ... 60 °C (+14 ... +140 °F)
20 g / 11 ms half-sine
3 g / 5 ... 500 Hz
IP40
Metal housing
2.8 kg
1 power on/off switch
2
2
/ EtherNet/IP