6 Programming and testing

6.10.2 Connected Services Reset service routine

6.10.2 Connected Services Reset service routine
Overview
It is possible to reset the software agent. When you reset, the software agent erases
all its internal information including the registration information, the data collector
script, and all the locally stored service information. The configuration will not be
reset, but a new registration is required to reactivate the connected services.
Procedure
Use the following procedure to reset the software agent using FlexPendant:
180
1 On the start screen, tap Operate, and then select Service Routines from the
menu.
2 Tap Connected Services Reset.
The ConnectedServicesReset window is displayed.
3 Tap Yes.
4 Press the START button on the FlexPendant.
A confirmation page is displayed with operator messages.
5 Tap Reset.
The software agent is reset.