10.3 Restart
Restart controller
ABB robot systems are designed to operate unattended for long times. There is
no need to periodically restart the functioning systems.
Restart the controller when:
Use the following procedure to restart the controller:
Using the QuickSet menu:
Using the Settings application:
Procedure
There are certain cases under which only the FlexPendant needs to be restarted.
For example, restart the FlexPendant while troubleshooting.
Use the following procedure to restart only the FlexPendant:
Operating manual - OmniCore
3HAC065036-001 Revision: J
10 Install, update, restart, and other configuration
•
new hardware has been installed.
•
the robot system configuration files have been changed.
•
a new system has been added and is to be used.
•
a system failure (SYSFAIL) has occurred.
Note
When the controller is restarted the FlexPendant is also restarted.
1 Tap on the QuickSet button and select the Logout/Restart tab.
The Logout/Restart page is displayed.
2 In the Controller section tap Restart.
The Restart window is displayed.
3 Tap OK.
The controller is restarted.
1 On the start screen, tap Settings.
The Settings page is displayed.
2 At the bottom of the Settings page tap Restart.
The Restart window is displayed.
3 Tap OK.
The controller is restarted.
Note
If the FlexPendant freezes during operation, press the reset button to restart the
FlexPendant. For more details, see
1 Tap on the QuickSet button and select the Logout/Restart tab.
The Logout/Restart page is displayed.
2 In the FlexPendant section tap Restart FlexPendant.
© Copyright 2019-2021 ABB. All rights reserved.
Reset button on page
18.
Continues on next page
10.3 Restart
249